A Filter That Catches Debris During Heart Valve Procedures

Emboline's Emboliner, cleared by the FDA in September 2026, uses a two-layer mesh filter to catch debris during TAVR before it can reach the brain or kidneys.

Photo source:

Emboline

Debris That Travels Through the Bloodstream

During a TAVR procedure, pieces of material such as calcified valve tissue, blood clots and foreign matter can break loose and enter circulation. Emboline states that this debris release occurs in every TAVR procedure, and that studies have found hundreds to thousands of particles entering the bloodstream during each one. The company lists stroke, cognitive decline and acute kidney injury among the complications such debris can cause, and says competing systems cover only selected vessels leading to the brain.

A Two-Layer Mesh With a Channel Through the Middle

The Emboliner uses a circumferential dual-layer filter made of nitinol mesh, a metal alloy, designed to balance blood flow with debris capture. A central working lumen, an open channel through the middle of the filter, lets the TAVR delivery system pass through, and an integrated port allows blood to keep flowing while particles are filtered out. The device is designed to protect both the brain and the rest of the body, including the kidneys, is compatible with leading self-expanding and balloon-expandable TAVR systems, and is retrieved once the procedure is complete.

Tested Head-to-Head Against Another System

Emboline's pivotal PROTECT H2H trial, presented as a late-breaking study at ACC 2026 with results announced on March 30, 2026, randomized 522 patients with severe aortic stenosis, a narrowing of the aortic valve, to receive either the Emboliner or Boston Scientific's SENTINEL Cerebral Protection System. Enrollment ran from May 2023 to December 2025. At 30 days, the combined rate of major adverse cardiac and cerebrovascular events was 4.5% with the Emboliner and 5.0% with the comparison device, and stroke rates were 2.0% and 2.1%. Both results met the trial's non-inferiority goals, meaning the Emboliner performed no worse than the comparison system.

What the Trial Found on Debris

Debris capture, measured for particles 150 micrometers or larger, came to 93 for the Emboliner and 31 for the comparison device, a statistically significant difference. Technical success reached 95.9% with the Emboliner compared with 87.1% for the comparison device, and access site injury and major bleeding did not differ significantly between the two groups. Emboline describes the technical success rate as the highest ever reported for a TAVR embolic protection device in a pivotal clinical study.

What the Trial Found on Debris

Debris capture, measured for particles 150 micrometers or larger, came to 93 for the Emboliner and 31 for the comparison device, a statistically significant difference. Technical success reached 95.9% with the Emboliner compared with 87.1% for the comparison device, and access site injury and major bleeding did not differ significantly between the two groups. Emboline describes the technical success rate as the highest ever reported for a TAVR embolic protection device in a pivotal clinical study.

First Procedures at Columbia

The first commercial Emboliner cases were two TAVR procedures on October 1, 2026, at New York-Presbyterian/Columbia University Irving Medical Center, performed by Tamim Nazif, MD, who co-directs the center's Structural Heart and Valve Center and served as co-principal investigator of PROTECT H2H. Nazif said, "Stroke and embolic debris remain concerns during TAVR, and there remains an unmet clinical need for more comprehensive and effective embolic protection for our patients." Emboline is launching in a controlled way, starting with leading structural heart centers, and CEO Scott Russell called the first cases "a defining milestone for Emboline."

Lock

You have exceeded your free limits for viewing our premium content

Please subscribe to have unlimited access to our innovations.